False Start Drain Valve
JASC False Start Drain Valve Product Description
JASC has designed a False Start Drain Valve (FSDV) to drain liquid fuel from combustion can(s) of industrial gas turbine engines in the event there is a false start. Based upon JASC’s experience with other industrial gas turbine valves, the JASC FSDV was designed with the following goals in mind: operate reliably for extended periods of time in a hot (400°F) environment, maintain low leakage, be tolerant of water, rust, scale, coking and a variety of particle contamination.
To help accomplish these goals, the JASC FSDV features a straight through poppet design (1.00 in. ID) that minimizes pressure drop and presents an optimum path for flushing contamination from the valve when de-energized and protects the sealing surfaces during engine operation. The FSDV also incorporates a unique crush seal to maintain low leakage for extended periods of operation.
![]() |
|
JASC False Start Drain Valve
|
Design Features and Benefits
The valve is normally spring loaded open and can be actuated closed with compressor discharge pressure at 5-10 psig (up to 300 psig maximum) or can be actuated closed with instrument air from 80 to 120 psig. JASC has designed the valve as a drop in replacement for the existing OEM FSDV design, with either NPT or Swagelok connections.